Performs
design of reinforced concrete structural wall sections for gravity,
wind, and seismic loads. StrucWall also computes and displays the
axial load-versus-moment capacity curve of the wall section.
In the Check mode, the program checks the adequacy of the structural
wall to carry the specified loads and verifies conformance to the
special seismic provisions of ACI 318 Chapter 21 and UBC Section 1921.6.
In the Design mode, the program determines the vertical and
horizontal reinforcement so that the wall section can adequately carry
the input loads and meet the special detailing requirements of ACI
318 Chapter 21 and UBC Section 1921.6. |
|
| Key
Features: |
| |
|
|
Design
Code: |
|
Units: |
|
Run
Mode: |
| |
-
ACI 318-02
- ACI 318-99
- IBC 2000
- UBC 97
- BS 8110 97 |
|
-
English
- Metric |
|
-
Check
- Design |
 |
Solution
Options: |
|
| |
-
Apply (or ignore) special seismic provisions.
- Control number of points on the interaction diagram. |
|
| |
|
|
 |
Wall
Section: |
|
|
| |
-
Rectangular web
- Web with columns
- Web with flanges
- Web with group of bars |
| |
|
 |
Reinforcement: |
|
| |
Up
to 1,000 bars may be specified.
Easy input for longitudinal and transverse bars in web and end
zone (column, flange, or bar group). |
| |
|
 |
Material
Properties: |
|
| |
-
Concrete strength, f'c, and modulus of elasticity, Ec.
- Reinforcing steel yield strength, fy, and modulus of elasticity,
Es.
- US, Canadian, European, Japanese and British bars. |
|
| |
|
|
 |
Load
Cases: |
 |
Loads: (per load case)
|
|
| |
-
Up to 6 load cases.
- Use built-in cases such as: Dead, Live, Wind and Seismic;
or define your own. |
|
-
Axial load, P
- Bending moment, Mx
- Horizontal shear, Vy |
| |
|
|
|
 |
Load
Combinations: |
|
| |
-
Up to 24 load combinations.
- Use built-in combinations that are based on the selected design
code; or define your own combinations. |
|
| |
|
|
 |
Solution: |
(Click to enlarge)
|
| |
-
Check bar spacings and reinforcement ratios. |
|
| |
- Factor
all loads per load combinations. |
| |
- Check
load-moment carrying capacity of the section. |
| |
-
Check need for and compute boundary elements. |
| |
- Compute
and check shear capacity. |
| |
- Check
confinement in the special boundary elements. |
| |
-
Compute additional confinement reinforcement in boundary element
and web. |
| |
-
Compute development length and splice length of bars. |
| |
- Compute
the P-M capacity curve. |
| |
- Compute
splice points on capacity curve. |
| |
 |
Graphics
and Output: |
(Click to enlarge)
|
| |
- Scaled graphical
view of the wall cross-section and input or computed longitudinal
and transverse reinforcement. |
|
| |
- Graphical view
of the P-M interaction diagram showing applied loads and splice
lines. |
| |
- Detailed listing
of all input data and computations. |
| |
- Text listing of
the interaction diagram points including neutral axis depth
for each point. |
| |
- Compare interaction
diagrams of up to 4 different wall sections. |
| |
|
 |
General
Features: |
(Click to enlarge)
|
| |
-
User-defined default input data. |
|
| |
-
User-defined color settings. |
| |
-
Ability to enter formulas in all edit boxes. |
| |
- Copy
text and graphics to the Windows clipboard. |
| |
-
Input Wizard to simplify the input process. |
| |
- On-line
help access from any dialog box. |
| |
- Electronic
user's manual including verification problems. |
| |
- User-friendly
interface. |
| |
|
|
| System
Requirements: |
 |
| |
StrucWall
is a Win32 application.
It is designed to run under Windows 98/Me/2000/XP.
|
| Price
(per license): |
Order... |
| |
First license |
$
695 |
| |
2 - 5 licenses |
$ 415
|
| |
6 or more
licenses |
$ 250
|
|